Technology
Air cooling, materials, and the thickness you can defend.
The useful comparison is not a slogan. It is what you stop maintaining, and the thickness at which you should stop promising.
Air-cooled against water-cooled
| Air-cooled handheld | Water-cooled handheld | |
|---|---|---|
| Move | One person, a van, a small bay | Chiller, hoses, more mass |
| Care | Vents, filters, protective windows | Water quality, leaks, freeze, biocide |
| Power class | 800–2000 W is the band this site sells | Often 1500–3000 W with a longer full-power duty |
| Hot shop | Duty falls as the room rises | The chiller holds the source |
| Field work | The reason the category exists | A poor fit |
| Thick plate | Coupon, or leave the category | More headroom, still not a structural procedure by itself |
| Supply | Usually 220–240 V single phase | Often higher current |
Material and thickness
Guides below match the product pages. About 1.5 mm is 16 gauge steel, 3 mm is about 11 gauge, 4 mm is about 8 gauge. Gauge language is only for the conversation.
| Material | LC-800 | LC-1200 | LC-1500 | LC-2000 |
|---|---|---|---|---|
| Stainless steel | 0.5–2.0 mm | 0.5–3.0 mm | 0.5–4.0 mm | 0.5–5.0 mm guide |
| Carbon steel | 0.5–2.0 mm | 0.5–3.0 mm | 0.5–4.0 mm | 0.5–5.0 mm guide |
| Galvanized steel | 0.5–1.5 mm | 0.5–2.0 mm | 0.5–3.0 mm | 0.5–4.0 mm |
| Aluminum | 0.5–1.2 mm, sample first | 0.5–2.0 mm | 0.5–3.0 mm | 0.5–4.0 mm guide |
| Brass | Sample only | Thin stock, sample first | Up to about 1.5 mm, sample first | Sample past 2 mm |
| Copper | Use LC-2000 and a coupon | Not the starting model | Sample only — prefer LC-2000 | Coupon required |
Thickness figures are selection guides for a sound joint, clean surface, and the gas named on the parameter sheet. They are not a weld procedure. The quotation states the configuration, and a coupon confirms an edge case.
What moves the result
- Gap. Contact welds behave. An open butt is a different job.
- Surface. Oil, scale, and zinc change the start of the bead and the fume.
- Reflection. Aluminum, brass, and copper need a sample sooner than stainless.
- Gas. Nitrogen is the usual stainless choice. Argon is the usual aluminum choice. The buyer supplies the bottle.
- Wire. Match the alloy. A feeder that slips will look like a laser problem.
- Angle and wobble. Use them to cover mismatch. Do not use them to hide a missing fixture.